Air conditioner size is determined by a load calculation that accounts for square footage, insulation, window area and orientation, ceiling height, and ductwork — not by square footage alone. In the Midlands, getting this wrong tends to mean oversizing, which produces a house that is cold and clammy at the same time.
An oversized air conditioner cools the air to the thermostat setting quickly and shuts off. That sounds efficient. The problem is that removing humidity takes time, and a system that runs in short bursts never runs long enough to dehumidify. In a dry climate you would barely notice. In South Carolina you end up with a house at 72 degrees that still feels damp, and the usual response is to lower the thermostat further, which makes it worse.
If the original system was oversized — and a great many installed before load calculations became standard practice were — then matching it simply locks in the same problem for another fifteen years. The fact that the old unit was three tons tells you what somebody chose once, not what your house needs.
Oversized: short run cycles, the house feels humid at a comfortable temperature, and the system clicks on and off frequently. Undersized: it runs almost constantly in July, never quite reaches the setting on the hottest days, and the house is noticeably warmer upstairs.
A correctly sized system on inadequate ductwork will still underperform. If the ducts are leaking or undersized, that has to be part of the conversation before anyone settles on a capacity. Any company sizing a system without looking at the ducts is doing half the job.
Short cycles, a house that never quite dries out, and a thermostat that keeps getting nudged lower to compensate for a comfort problem that is not about temperature. Over time the compressor wears faster from repeated starts, and the homeowner concludes the brand was poor. The equipment was usually fine. The sizing was not.
Variable speed and multi-stage equipment runs at lower output for longer rather than switching fully on and off. That is exactly what dehumidification needs, and it makes a system considerably more forgiving if the sizing is slightly generous. It costs more and in a humid climate it earns a genuine share of that back in comfort rather than just in efficiency.
Any company performing a proper load calculation can show you the output. If the answer to "how did you arrive at that size" is the size of the old unit or the square footage of the house, you have learned something important about how the quote was produced.
No. Square footage is one input among several. Rules of thumb based on it alone are how oversizing happens.
A unit of cooling capacity. Residential systems are commonly between one and a half and five tons, and the right figure comes from the load calculation.
Neither, but in a humid climate slight undersizing is usually more liveable than oversizing, because at least the system runs long enough to dehumidify.
It is part of our estimate process on replacements, and our estimates on new installations are free.
Long cycles are normal and desirable in peak heat. Constant running that never reaches the setting indicates a problem. Very short cycles suggest oversizing.