An air conditioner leaking water is almost always a blocked condensate drain, a frozen evaporator coil that has thawed, a cracked drain pan, or a disconnected drain line. In a humid climate like the Midlands the drain line handles a great deal of water, and a blockage shows up quickly.
Your air conditioner removes moisture from the air, and in a Columbia summer that is a substantial volume of water every day. It all exits through one drain line. Algae growth inside that line is a slow, quiet process until the day it blocks completely, and then the water finds somewhere else to go — usually a ceiling.
If water is actively dripping, turn the system off at the thermostat. Continuing to run it keeps producing condensate with nowhere to drain. This is the rare case where turning it off during a heat wave is genuinely the right call.
Most properly installed systems have a float switch that shuts the unit down when the drain pan fills, specifically to prevent water damage. If your system kept running and leaked anyway, either there is no float switch or it has failed. Worth having checked, because it is the difference between an inconvenience and a ceiling repair.
Condensate drain clearing is part of an annual AC maintenance visit. It is one of the least glamorous things on the checklist and one of the most financially worthwhile, because water damage costs far more than the tune-up that would have prevented it.
An air handler in an attic leaks downward into ceilings, and the damage is often substantial before anyone notices a stain. Attic units should have a secondary drain pan beneath them and a float switch that shuts the system down when that pan fills. If yours does not, that is worth adding — it costs far less than the ceiling repair it prevents.
The volume of water your system pulls out of Midlands air across a summer is considerable, and all of it goes down one line. Algae grows in that line continuously through the season. It is not a question of whether debris accumulates but of whether it gets cleared before it blocks, which is precisely why drain clearing is on the annual maintenance list.
Switch the system off, mop up what you can reach, and get air moving in the affected area. If water has reached drywall or insulation, it needs drying properly rather than being left to sort itself out. Then get the cause fixed before running the system again, because it will simply produce more.
No. Condensate should go entirely through the drain line. Visible water means something is wrong.
Sometimes, with a wet vacuum at the outdoor end. If the blockage is further in, or if the pan is cracked, it needs a technician.
Usually low refrigerant or restricted airflow from a dirty filter or blocked return. The ice then melts and floods the pan.
Urgent enough to switch the system off now. Water in a ceiling or wall cavity becomes a much larger problem quickly.
Largely yes. Drain clearing and coil cleaning address the two most common causes directly.