The most common air conditioner failures are capacitors, blocked condensate drains, refrigerant leaks, dirty coils, failed contactors and frozen evaporator coils. A large share of them trace back to two preventable causes: neglected filters and skipped maintenance.
A capacitor gives the compressor and fan motor the jolt they need to start. They degrade with heat, and a Columbia summer provides plenty of it. This is the single most common part we replace, it is inexpensive, and it is routinely caught during a spring tune-up before it strands anyone in July.
Your system pulls a great deal of water out of Midlands air and sends it all down one line. Algae builds up quietly and blocks it. On a system with a working float switch you get a shutdown. On one without, you get water in a ceiling. Clearing the drain takes minutes during maintenance.
A blocked filter restricts airflow, which freezes the evaporator coil, which stops the system cooling and then floods the drain pan when it thaws. It can also overheat the blower motor. Filters are the cheapest component in the entire system and neglecting them causes some of the most expensive consequences.
Refrigerant is not consumed. If a system is low, it is leaking. Simply topping it up without finding the leak means paying for refrigerant repeatedly and venting it into the atmosphere. We look for the leak.
A condenser coil packed with grass clippings, leaves and dust cannot shed heat. The system runs longer, costs more and wears faster. Keeping a couple of feet clear around the outdoor unit does much of this for free.
Thermostat set to cool and fan on auto. Breaker not tripped. Filter not blocked. Outdoor unit not packed with debris. Those four take two minutes and cover a meaningful share of the calls that turn out not to need a technician at all.
Capacitors, blocked condensate drains, frozen coils from airflow restriction and dirty coils between them account for a large majority of the summer calls we attend. Every one of those is either caught or prevented by an annual visit and a regularly changed filter. That does not mean maintenance eliminates repairs — but the preventable proportion is high enough to be worth acting on.
Refrigerant is not consumed and does not degrade. A system that is low is leaking, full stop. Topping it up without locating the leak means paying for refrigerant again next season, venting it into the atmosphere, and leaving the compressor running under conditions it was not designed for. Any company that recharges without looking for the leak is selling you the same repair repeatedly.
What failed, why it failed, whether it is likely to have damaged anything else, what it costs to fix, and what the realistic remaining life of the system is afterwards. Price before work begins. If a technician cannot answer the second and fifth of those, you are being given a part number rather than a diagnosis.
Capacitor replacement, by a clear margin, particularly during peak heat.
Every one to three months for standard filters, depending on thickness, pets and household size.
Usually restricted airflow from a dirty filter or blocked return, or low refrigerant from a leak.
It prevents a good share of them, particularly capacitor failures, drain blockages and coil problems. It cannot prevent everything.
No. Low refrigerant means a leak, and the leak is the repair.
Call (803) 888-4115 or get in touch. Kaminer Heating And Cooling, 110 Kaminer Way Pkwy, Columbia, SC 29210. Serving Columbia, Irmo, Blythewood, Chapin, Cayce, Lexington, Seven Oaks and West Columbia.